| SYSTEM | 
        
            | Frequency Response (-3dB) (1) BM Back can | 47Hz – 30kHz | 
        
            | Frequency Range (-10dB) (1) BM Back can | 40Hz – 35kHz | 
        
            | Frequency Range (-10dB) (1) PI Back can | 41Hz – 35kHz | 
        
            | System Sensitivity (1W @1m) (2) | 92dB (1W = 2.83V for 8 Ohms) | 
        
            | Nominal Coverage Angle | 90 degrees conical | 
        
            | Coverage Angle (1kHz to 6kHz) | 100 degrees | 
        
            | Directivity Factor (Q) | 5.5 averaged 1kHz to 6kHz | 
        
            | Directivity Index (DI) | 7.2 averaged 1kHz to 6kHz | 
        
            | Rated Maximum SPL | Average: 112dB Peak: 118dB
 Average: 110dB (with THP60)
 | 
        
            | Power Handling (3) | Average: 90W Programme: 180W
 Peak: 360W
 | 
        
            | Recommended Amplifier Power | 180W @ 8 Ohms | 
        
            | Nominal Impedance | 8 Ohms | 
        
            | Transformer Taps (via front rotary switch) | 70V: 60W / 30W / 15W / 7.5W / OFF & Low Impedance operation
 100V: 60W / 30W / 15W / OFF
 & Low Impedance operation
 | 
        
            | Crossover | 2kHz – 2nd order LF, 2nd order HF (with dynamic HF protection)
 | 
        
            | TRANSDUCERS | 
        
            | Low Frequency | 1 x 200mm (8.00″) Dual Concentric™ constant directivity driver with multi fibre paper pulp cone | 
        
            | High Frequency | 1 x 25mm (1.00″) titanium dome with neodymium magnet system | 
        
            | PHYSICAL | 
        
            | Enclosure | Back Can: Zinc plated steel Baffle: Reflex loaded UL 94V-0 rated ABS Grille: Steel, with weather resistant coating
 | 
        
            | Safety Features | Safety ring located at rear of enclosure for load bearing safety bond | 
        
            | Clamping Design | Min / Max clamping range: 0.0mm (0.0″) / 20.0mm (0.79″) Recommended clamp torque: 1.5Nm
 | 
        
            | Back Can Options | Blind Mount (BM): Complete with fixed back can Pre Install (PI): Separate back can for pre installation
 | 
        
            | Cable Entry Options | Cable clamp & squeeze connector for conduit up to 22mm
 | 
        
            | Conduit Knockouts | 3 Sets of horizontal positions: 19 / 22 / 28mm 0.75 / 0.87 / 1.10″ | 
        
            | Connectors | Removable locking connector with screw terminals with “loop through” facility | 
        
            | Safety Agency Ratings | CE, UL-1480, UL-2043 | 
        
            | BM Hole Cutout Diameter | 295mm (11.61″) | 
        
            | PI Hole Cutout Diameter | 295mm (11.61″) | 
        
            | Dimensions | Bezel diameter: 325mm (12.80″)BM model: Front of ceiling to rear of back can 310.50mm (12.22″) BM model: Front of ceiling to top of safety loop 327.80mm (12.90″)PI model: Front of ceiling surface to rear of speaker unit 118.70mm (4.67″)
 PI model: Front of accessory back can bezel to top of safety loop 168.50mm (6.63″)
 |